BCSTY - PLASTIC STEEL (S-5) HARDENER

  • MSDS: BCSTY
  • Manufacturer: DEVCON CORP
  • Product Name: PLASTIC STEEL (S-5) HARDENER
  • National Stock Number: 6850-00N009586
Product Identification

Product ID:PLASTIC STEEL (S-5) HARDENER
MSDS Date:04/01/1987
FSC:6850
NIIN:00N009586
MSDS Number: BCSTY

Responsible Party
DEVCON CORPORATION
30 ENDICOTT STREET
DANVERS, MA 01923

Emergency Phone: 617-777-1100

Info Phone: 617-777-1100

Cage: 16059

Contractor
DEVCON CORP
DANVERS, MA 01923-3753 US

Telephone: 1-508-777-1100

Cage: 16059

Ingredients

2,4,6-TRI(DIMETHYLAMINOMETHYL)PHENOL (DMP)

CAS: 90-72-2

RTECS: SN3500000

Fraction By Weight: 1-5%

OSHA PEL OSHA PEL

ACGIH TLV: ACGIH TLV


TALL OIL FATTY ACID AMIDE OF TETRAETHYLENE PENTAMINE

CAS: 68155-17-9

Fraction By Weight: 5-10%

OSHA PEL OSHA PEL

ACGIH TLV: ACGIH TLV


TRIETHYLENE TETRAMINE (TETA)

CAS: 112-24-3

RTECS: YE6650000

Fraction By Weight: 1-5%

OSHA PEL OSHA PEL

ACGIH TLV: ACGIH TLV


TETA/C*18 FATTY ACID DIMER POLYAMIDE

CAS: 68410-23-1

Fraction By Weight: 10-30%

Hazards

LD50 LC50 Mixture:5PPM(SUGGEST FOR(DMP)(SEE SUP DATA)
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SEE SIGNS & SYMPTOMS OF OVEREXPOSURE
Explanation of Carcinogenicity:N/A
Effects of Overexposure:ACUTE,EYE:SEVERE IRRITATION OR
BURNS.SKIN:SEVERE IRRIT OR BURN.INHAL:UNLIKELY BECAUSE OF LOW VAPOR
PRESS.RESP IRRITATION.CHRONIC:RPT SKIN/RESP CONTACT MAY CAUSE
SENSITIZATION W/ ASTHMATIC OR ALLERGIC SYMPTOMS ON LATER
EXPOS.CHRONIC OVEREXPOS TO DMP HAS BEEN RPTD TO CAUSE DELAYED LUNG
INJURY & CHEMICAL PNEUMONIA
Medical Cond Aggravated by Exposure:NONE REPORTED

First Aid

First Aid:EYE:RINSE CLEAR H*2O IN A GENEROUS,LOW-PRESS STREAM FOR AT
LEAST 15 MIN. 1% BORIC ACID RINSE USED.SEE PHYS IMMED.SKIN:REMOVE
CONTAM CLOTH,SHOES,WASH W/ MILD SOAP & H*2O.LAUNDER CLOTH BEFORE
REUSE CONT ACT PHYS IF IRRIT PERSISTS.INGEST:DO NOT INDUCE
VOMITING.GIVE MILK & H*2O.GET MED HELP.INHAL:REMOVE TO FRESH
AIR.SEE PHYS IF SYMPTOM PERSISTS.

Fire Fighting

Flash Point Method:TOC
Flash Point:250.F,121 C.
Extinguishing Media:CARBON DIOXIDE,DRY CHEMICAL,FOAM
Fire Fighting Procedures:FIREFIGHTERS SHOULD WEAR SCBA & PROTECTIVE
CLOTHING
Unusual Fire/Explosion Hazard:NONE

Accidental Release

Spill Release Procedures:PREVENT SKIN EYE CONTACT.SCRAPE UP & TRANSFER
TO SUITABLE CLOSED CONTR.CLEAN SPILL AREA W/ STRONG DETERGENT &
H*2O REMOVE CONTAM CLOTHING & LAUNDER BEFORE REUSE;DISCARD
CONTAMINATED LEATHER ARTICLES.
Neutralizing Agent:

Handling

Handling and Storage Precautions:STORE WELL-CLOSED IN A COOL,DRY PLACE.
KEEP HANDS AWAY FROM EYES WHEN HANDLING THIS MATERIAL.

Exposure Controls

Respiratory Protection:NO SPECIAL PROTECTION NEEDED W/ GOOD VENT.IN
POORLY VENT AREAS WEAR NIOSH APPROVED ORGANIC VAPOR RESPIRATOR.
Ventilation:LOCAL EXHAUST IS RECOMMENDED FOR PROLONGED/RPTED
USE.EFFECTIVE MECH EXHAUST IS ADEQUATE FOR OCCASIONAL USE.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:SAF GLAS W/SIDESHIELD OR CHEM WORK GOGG
Other Protective Equipment:
Work Hygienic Practices:WASH THOROUGHLY AFTER USING ESPECIALLY BEFORE
EATING OR SMOKING
Supplemental Safety and Health
LD50-LC50 MIX:ORAL LD&50(RAT)1653MG/KG(DMP)DERMAL LD*50
(RABBIT)1350MG/KG(DMP):INHAL:LC*50(RAT)>0.5MG/LITER(DMP)

Chemical Properties

Boiling Pt:B.P. Text:>400 F,204C
Melt/Freeze Pt:M.P/F.P Text:NA
Decomp Temp:Decomp Text:
Vapor Pres:<1
Vapor Density:>1
Spec Gravity:1.73
pH:10.5
Evaporation Rate & Reference:<1 BUAC EQUALS 1
Solubility in Water:APPRECIABLE
Appearance and Odor:OFF-WHITE PASTE W/ AMMONIA-LIKE ODOR
Percent Volatiles by Volume:0
Corrosion Rate:

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS,ACIDS,CHLORINATED ORGANIC COMPOUNDS
Stability Condition to Avoid:EXTREME HEAT OR OPEN FLAME
Hazardous Decomposition Products:ACRID & TOXIC FUMES INCLUDING ORGANIC
AMINES,AMMONIA,CARBON MONOXIDE,CARBON DIOXIDE & OXIDES OF NITROGEN
Conditions to Avoid Polymerization:HEAT IS GEN WHEN THIS HARDENER REACT
W/ ACID,ISOCYANATES & EPOXY RESINS.MIX ONLY AS INSTRUCTED & USE
CAUT,MIX LG QTYS

Disposal

Waste Disposal Methods:DISPOSE OF AS A HAZARDOUS WASTE IN ACCORDANCE W/
FEDERAL,STATE & LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.